DESCRIPTION
Start Indicator light: START(red) light, meaning relay is closed, device start working;
Stop Indicator light: STOP(green) light, meaning relay is off,device stop working;
Screen:Middle red number means the detected temperature;
Left green number means the set start temperature;
Right green number means the set stop temperature;
Arrow(down or up) means to set temperature.
1. High temperature start – Cooling Mode: Set the starting temperature> stop temperature, when the detected temperature ≥ start temperature, the relay is closed, refrigeration equipment work; when the detected temperature ≤ stop temperature, the relay is off, refrigeration equipment stops working. For example: Set the start temperature is 30 ℃, stop temperature is 25 ℃, when the detected temperature ≥30 ℃, the relay is closed, start indicator (red) light; when the detected temperature ≤25 ℃, the relay off, stop instruction light (green) light.
2. Low temperature start – Heating mode: Set the start temperature
FEATURES
- A simple Temperature Sensor Module with 30A Relay.
- Model: XH-W1401
- Thermostat Range: -9℃ to 99℃
- Thermostat Accuracy: 1℃
- Power Supply: DC9-12V
- Output: Electric relay output ,capacity 220V 10A/12V 10A
- For cooling or heating temperature control
ALSO SEARCHED AS:
XH-W 1401 Temperature Sensor Module